Freescale Semiconductor /MKE16F16 /CMP2 /C0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as C0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (00)HYSTCTR 0 (0)OFFSET 0 (000)FILTER_CNT 0 (0)EN 0 (0)OPE 0 (0)COS 0 (0)INVT 0 (0)PMODE 0 (0)WE 0 (0)SE 0FPR0 (COUT)COUT 0 (0)CFF 0 (0)CFR 0 (0)IEF 0 (0)IER 0 (0)DMAEN

FILTER_CNT=000, PMODE=0, INVT=0, WE=0, SE=0, IEF=0, CFF=0, EN=0, IER=0, OPE=0, CFR=0, DMAEN=0, HYSTCTR=00, COS=0, OFFSET=0

Description

CMP Control Register 0

Fields

HYSTCTR

Comparator hard block hysteresis control. See chip data sheet to get the actual hystersis value with each level

0 (00): The hard block output has level 0 hysteresis internally.

1 (01): The hard block output has level 1 hysteresis internally.

2 (10): The hard block output has level 2 hysteresis internally.

3 (11): The hard block output has level 3 hysteresis internally.

OFFSET

Comparator hard block offset control. See chip data sheet to get the actual offset value with each level

0 (0): The comparator hard block output has level 0 offset internally.

1 (1): The comparator hard block output has level 1 offset internally.

FILTER_CNT

Filter Sample Count

0 (000): Filter is disabled. If SE = 1, then COUT is a logic zero (this is not a legal state, and is not recommended). If SE = 0, COUT = COUTA.

1 (001): 1 consecutive sample must agree (comparator output is simply sampled).

2 (010): 2 consecutive samples must agree.

3 (011): 3 consecutive samples must agree.

4 (100): 4 consecutive samples must agree.

5 (101): 5 consecutive samples must agree.

6 (110): 6 consecutive samples must agree.

7 (111): 7 consecutive samples must agree.

EN

Comparator Module Enable

0 (0): Analog Comparator is disabled.

1 (1): Analog Comparator is enabled.

OPE

Comparator Output Pin Enable

0 (0): When OPE is 0, the comparator output (after window/filter settings dependent on software configuration) is not available to a packaged pin.

1 (1): When OPE is 1, and if the software has configured the comparator to own a packaged pin, the comparator is available in a packaged pin.

COS

Comparator Output Select

0 (0): Set CMPO to equal COUT (filtered comparator output).

1 (1): Set CMPO to equal COUTA (unfiltered comparator output).

INVT

Comparator invert

0 (0): Does not invert the comparator output.

1 (1): Inverts the comparator output.

PMODE

Power Mode Select

0 (0): Low Speed (LS) comparison mode is selected.

1 (1): High Speed (HS) comparison mode is selected, in VLPx mode, or Stop mode switched to Low Speed (LS) mode.

WE

Windowing Enable

0 (0): Windowing mode is not selected.

1 (1): Windowing mode is selected.

SE

Sample Enable

0 (0): Sampling mode is not selected.

1 (1): Sampling mode is selected.

FPR

Filter Sample Period

COUT

Analog Comparator Output

CFF

Analog Comparator Flag Falling

0 (0): A falling edge has not been detected on COUT.

1 (1): A falling edge on COUT has occurred.

CFR

Analog Comparator Flag Rising

0 (0): A rising edge has not been detected on COUT.

1 (1): A rising edge on COUT has occurred.

IEF

Comparator Interrupt Enable Falling

0 (0): Interrupt is disabled.

1 (1): Interrupt is enabled.

IER

Comparator Interrupt Enable Rising

0 (0): Interrupt is disabled.

1 (1): Interrupt is enabled.

DMAEN

DMA Enable

0 (0): DMA is disabled.

1 (1): DMA is enabled.